The main parameters when selecting an solenoidcoil pump to be considered
1. Use of voltage and frequency (Rating):
As 220VAC 50Hz or 120VAC 60Hz
2. Power
As 16W (Rating)
3. Insulation (temperature) level (Class) :
A level 105 ℃ (temperature ≤75 K)
Class B 130 ℃ (temperature ≤90 K)
Grade F 155 ℃ (temperature ≤115 K)
Class H 180 ℃ (temperature ≤140 K)
C-class 220 ℃ (temperature ≤180 K)
Note: T (℃) = [T (F) -32)] * 5/9
4. work
ED100% - Continuous pumping 2min / 1min --- pumped 2 minutes / stop 1 minutes (intermittent pumping)
5. Use of the environment
Ambient temperature, such as Ta max: 60 ℃
Fluid temperature, e.g. Tf max: 35 ℃
6. The maximum pressure
Such as: 15Bar (required operating pressure as much as possible within 70% of the maximum pressure)
7. The work flow under pressure, such as 160g / min (@ 10Bar)
Flow - pressure curve (flow rate-pressure curve)
In general, the pump flow rate will increase as the operating pressure is reduced, the maximum flow rate when 0Bar, completely blocking flow rate to 0, the greatest pressure.